Dongguan MLF Tech Co.,Ltd

Set production, development, sales, one-stop service

Sales service phone

+86 0769 87989659

D36 2C+1A GaN 120W Charger
  • D36 2C+1A GaN 120W Charger
  • D36 2C+1A GaN 120W Charger
  • D36 2C+1A GaN 120W Charger
  • D36 2C+1A GaN 120W Charger
  • D36 2C+1A GaN 120W Charger

D36 2C+1A GaN 120W Charger

Input: 100-240V 50/60Hz 1.0A max

Single port mode: USB-A QC3.0: 5V3A / 9V3A / 12V3A /  20V1.5A 60W Max

                              USB-C1 PD3.0: 5V3A / 9V3A / 12V3A / 15V3A / 20V5A 100W 

                              USB-C2 PD3.0: 5V3A / 9V3A / 12V3A / 15V3A / 20V5A 100W Max

Dual port mode:USB-A+USB-C1:20W+100W 130W Max

                           USB-A+USB-C2:25W Max

                           USB-C1+USB-C2: 60+60W 120W Max

Three port mode:USB-C1+USB-C2+USB-A:60W+30W+30W Max

                             PPS:3.3-21.0  63.0W Max 

Applicable plugs: EU,US,UK

Dimension: 75*75*28.5mm

Protection: OVP OCP SCP OTP

Quality warranty: 24 months

Certificate: CE RoHS


  • Product overview

I. Product features:

1. Shell material: PC/ABS+PC, 120℃ high temperature resistance, fireproof rating: UL 94V-0;

Constant pressure working mode :±5%;

3. Brand IC scheme design, stable and reliable performance, low loss;

4. Environmental protection conforms to RoHS 2.0;

II, electrical characteristics:

1. Input voltage/frequency: AC 100 ~ 240V (90 ~ 264V), 50/60Hz (47/63Hz)

2. Output power: PD65W

3. Output voltage :100-240V~50/60Hz 0.6a Max

4. Output current:

                 USB-A QC3.0: 5V3A / 9V3A / 12V3A /  20V1.5A 60W Max

                 USB-C1 PD3.0: 5V3A / 9V3A / 12V3A / 15V3A / 20V5A 100W Max

                 USB-C2 PD3.0: 5V3A / 9V3A / 12V3A / 15V3A / 20V5A 100W Max

5. Load adjustment range: ± 5%

6. Energy efficiency: meets class VI

7. Pressure test: AC 3000V/Min 5Ma/3S

8. Insulation impedance: DC 500V 100M ω

III, protection function:

1. Overcurrent protection: 120%

2. Overvoltage protection: 120%

3. Short circuit protection: automatic recovery

IV. Reliability Test:

1. Aging test: the product should be aged at least 2 hours in an environment of 40℃±5℃ and under 100% rated load conditions;

2. MTBF(mean time between failures): at least 50000 hours, at 25℃ and under input and full load conditions;

3. Drop test: 1M high, drop onto hardwood 30mm thick, and hardwood should be placed on cement base or equivalent inelastic floor;

VI, environmental requirements:

1. Operating temperature: 0 ~ 40℃

2. Storage temperature: -20 ~ 85℃

3. Working humidity: 5 ~ 95%RH

VII, safety certification:

CE RoHS